InBody 270 vs seca mBCA Alpha
InBody 270 and seca mBCA Alpha: compare documented specifications, features and limitations. Check the reports and explanation offered by the provider. More features alone do not establish better accuracy.
InBody 270: when to consider it
The original InBody270 gives a quick overview of fat, muscle and their distribution. It suits regular diet and training consultations, including testing at different locations. Its output coverage differs from the newer 270S.
seca mBCA Alpha: when to consider it
mBCA Alpha is an eight-point BIA analyser using nine frequencies. Documentation lists a 24-second recording, 360 kg capacity and fat, skeletal-muscle mass and phase-angle outputs. The Alpha configuration contains the mBCA 554 platform and mBCA 545 handle.
Specifications side by side
Highlighted rows differ. Unknown values stay unknown.
| Specifications | InBody 270 | seca mBCA Alpha |
|---|---|---|
| Recording time | ≈ 15 s | 24 s; excluding preparation and consultation |
| Body weight range | 10–250 kg | Not verified |
| Height range | 95–220 cm | Not verified |
| Device weight | 14 kg | Not verified |
| Measurement frequencies | 20, 100 kHz | 1, 2, 5, 10, 20, 50, 100, 200, 500 kHz |
| Contact electrodes | 8 | Not verified |
| Measurement position | Standing | Not verified |
| Operating temperature | 10–40 °C | Not verified |
| Method | Not verified | Multi-frequency BIA |
| Maximum weight | Not verified | 360 kg |
| Documented outputs | Not verified | Fat, skeletal-muscle mass and phase angle |
| Dimensions (width × depth × height) | 356 × 796 × 995 mmEvidence | Not verified |
| Age in the cited catalogue | 3–99 yearsEvidence | Not verified |
| Impedance measurements | 10Evidence | Not verified |
| Device internal database capacity | 100,000 recordsModel sources | Not verified |
| Display | 7″ colour touchscreen LCD, keypadModel sources | Not verified |
| Display diagonal | 7″Model sources | Not verified |
| Documented interfaces | RS-232C, USB, LAN, Bluetooth, Wi-FiModel sources | Not verified |
| Electrodes | 8 contact points on hands and feetModel sources | Not verified |
| Report types | Adult, child and optional thermal reportsModel sources | Not verified |
Fat-free mass is not pure muscle mass. A single result is not a diagnosis. Different devices and similarly named metrics may use definitions that are not interchangeable.
Sources and verification
- Nutriamb, Jindřichův Hradec — měření InBody 270
- InBody 270 — originální katalog BC-ENG-83-D-220121
- InBody 270 — český uživatelský manuál
- InBody Japan — změna specifikace 270 → 270S (12. 11. 2024)
- InBody USA — The InBody Test
- Ne hladu — měření InBody230 a 270 / InBody230 and 270 testing
- InBody Japan — BIA and InBody history
- InBody — historie modelů 230 a 270 / history of models 230 and 270