InBody 370S vs Tanita SC-240MA
InBody 370S and Tanita SC-240MA: compare documented specifications, features and limitations. Check the reports and explanation offered by the provider. More features alone do not establish better accuracy.
Tanita SC-240MA
0 locations in Slovakia
Find locations using this deviceInBody 370S: when to consider it
InBody370S provides a detailed muscle-and-fat overview for training or nutrition consultations. Alongside whole-body values, it shows regional distribution and visceral fat level. It suits repeat monitoring when you will make use of those measures.
Tanita SC-240MA: when to consider it
SC-240MA is a standing BIA platform analyser. It uses one 50 kHz frequency and a 200 kg scale. The manual’s specification table lists weight, body-fat percentage and BMI; separate arm and trunk results are not documented.
Specifications side by side
Highlighted rows differ. Unknown values stay unknown.
| Specifications | InBody 370S | Tanita SC-240MA |
|---|---|---|
| Recording time | ≈ 15 s | Not verified |
| Body weight range | 10–250 kg | Not verified |
| Height range | 95–220 cm | Not verified |
| Device weight | 26 kg | Not verified |
| Measurement frequencies | 5, 50, 250 kHz | 50 kHz |
| Contact electrodes | 8 | Not verified |
| Measurement position | Standing | Standing |
| Operating temperature | 10–40 °C | Not verified |
| Method | Not verified | Bioelectrical impedance (BIA) |
| Maximum weight | Not verified | 200 kg |
| Documented outputs | Not verified | Weight, body fat (%), BMI |
| Dimensions (width × depth × height) | 522 × 874 × 1,059 mmEvidence | Not verified |
| Age in the cited catalogue | 3–99 yearsEvidence | Not verified |
| Impedance measurements | 15Evidence | Not verified |
| Device internal database capacity | 100,000 recordsEvidence | Not verified |
| Display | Colour TFT LCD with touchscreen and keypadEvidence | Not verified |
| Display diagonal | 7″Model sources | Not verified |
| Documented interfaces | RS-232C, USB, LAN, Bluetooth and Wi-Fi according to the manual; Lookin’Body. Blood pressure requires an external monitor.Model sources | Not verified |
| Result sheets | Standard adult and children’s sheets; optional thermal printingModel sources | Not verified |
| Connectable accessories | Stadiometer, external blood pressure monitor and printer, subject to compatibilityModel sources | Not verified |
Fat-free mass is not pure muscle mass. A single result is not a diagnosis. Different devices and similarly named metrics may use definitions that are not interchangeable.