Comparison

InBody 120 vs InBody 380

InBody 120 and InBody 380: compare documented specifications, features and limitations. Check the reports and explanation offered by the provider. More features alone do not establish better accuracy.

InBody 120: when to consider it

InBody120 is useful for following fat and muscle while changing your diet or activity. A meaningful consultation benefits from the full computer-generated report; the small display shows only part of the results.

InBody 380: when to consider it

For following fat and muscle changes at a gym, nutrition practice or mobile testing event. Adds a body-water ratio and whole-body phase angle to the usual overview for discussion during a consultation.

Specifications side by side

Highlighted rows differ. Unknown values stay unknown.

SpecificationsInBody 120InBody 380
Recording time≈ 17 s≈ 30 s
Body weight range5–250 kg5–300 kg
Height range50–300 cm95–220 cm
Device weight4.3 kg16 kg
Measurement frequencies20, 100 kHz5, 50, 500 kHz
Contact electrodes88
Measurement positionStandingStanding
Operating temperature10–40 °C10–40 °C
Dimensions (width × depth × height)392 × 434 × 55.2 mm · without the optional standEvidence415.5 × 871.5 × 1,069.9 mmEvidence
Age in the cited catalogue3–99 yearsEvidenceFrom 3 yearsEvidence
Impedance measurements10Evidence15Evidence
Display48 × 24 mm FSTN LCDEvidence7″ touchscreen TFT LCD, 480 × 800Evidence
Documented interfacesRS-232C and Bluetooth; detailed report through LookinBodyModel sources2× RS-232C, 2× USB host, Ethernet, Bluetooth and Wi-FiModel sources
PowerFour AA batteries or a mains adapterModel sourcesNot verified
Optional stand393 × 516 × 732 mm; total weight with stand 5.7 kgModel sourcesNot verified
Report formatsScreen, optional thermal printer, full report through LookinBodyModel sourcesNot verified
ControlsButtons and a separate handpiece; height is enteredModel sourcesNot verified
Device internal database capacityNot verified100,000 recordsEvidence
Display diagonalNot verified7″Model sources
ConstructionNot verifiedFolding column and three-way hand electrodesModel sources
Result sheetsNot verifiedBody composition, child and thermal reportsModel sources
Client identificationNot verifiedID entry and QR recognition option; depends on equipmentModel sources
Operating modesNot verifiedProfessional and self-service modesModel sources

Fat-free mass is not pure muscle mass. A single result is not a diagnosis. Different devices and similarly named metrics may use definitions that are not interchangeable.