InBody S10 vs Tanita MC-780
InBody S10 and Tanita MC-780: compare documented specifications, features and limitations. Check the reports and explanation offered by the provider. More features alone do not establish better accuracy.
InBody S10: when to consider it
The S10 measures composition and body water without requiring you to stand on a scale. Its electrodes attach separately, allowing lying or seated testing. You will mainly encounter it in clinical care and rehabilitation.
Tanita MC-780: when to consider it
The MC-780 family uses multi-frequency segmental BIA to report fat, muscle mass and body water, including regional results. A base designation does not identify the P/S configuration or MA/MA-N generation.
Specifications side by side
The filter keeps rows with undocumented values. More features or a different value alone do not establish better measurement accuracy.
Practical specifications
| Specification | InBody S10 | Tanita MC-780 |
|---|---|---|
| Recording timeA documented value is missing | 90–130 sModel sources 1Model sources 2Model sources 3Model sources 4Model sources 5 | Not documented |
| Body weight rangeA documented value is missing | 10–250 kgModel sources 1Model sources 2Model sources 3Model sources 4Model sources 5 | Not documented |
| Height rangeA documented value is missing | 95–220 cmModel sources 1Model sources 2Model sources 3Model sources 4Model sources 5 | Not documented |
| Measurement positionA documented value is missing | Supine, seated or standingModel sources 1Model sources 2Model sources 3Model sources 4Model sources 5 | Not documented |
| Age in the cited catalogueA documented value is missing | 3–99 yearsEvidence | Not documented |
| Documented outputsA documented value is missing | Not documented | Fat, muscle mass, body water; regional resultsModel sources |
| Designation scopeA documented value is missing | Not documented | Family; variant unspecifiedModel sources |
Technical specifications
| Specification | InBody S10 | Tanita MC-780 |
|---|---|---|
| Device weightA documented value is missing | 2 kgModel sources 1Model sources 2Model sources 3Model sources 4Model sources 5 | Not documented |
| Measurement frequenciesA documented value is missing | 1, 5, 50, 250, 500 kHz; 1 MHzModel sources 1Model sources 2Model sources 3Model sources 4Model sources 5 | Not documented |
| Contact electrodesA documented value is missing | 8Model sources 1Model sources 2Model sources 3Model sources 4Model sources 5 | Not documented |
| Operating temperatureA documented value is missing | 10–40 °CModel sources 1Model sources 2Model sources 3Model sources 4Model sources 5 | Not documented |
| Dimensions (width × depth × height)A documented value is missing | 202 × 322 × 53 mmEvidence | Not documented |
| Impedance measurementsA documented value is missing | 30Evidence | Not documented |
| Reactance measurementsA documented value is missing | 15Evidence | Not documented |
| Device internal database capacityA documented value is missing | 100,000 recordsEvidence | Not documented |
| DisplayA documented value is missing | Colour LCD, 800 × 480 pixelsEvidence | Not documented |
| Documented interfacesA documented value is missing | RS-232C, USB Host and USB SlaveEvidence | Not documented |
| Electrode typesA documented value is missing | Tactile or adhesive; depending on circumstances and accessoriesModel sources | Not documented |
| Weight for the testA documented value is missing | Entered separately; the device has no built-in scaleModel sources | Not documented |
| TransportA documented value is missing | Portable analyser; trolley and bag are accessoriesModel sources | Not documented |
| MethodA documented value is missing | Not documented | Multi-frequency BIAModel sources |
| Measured regionsA documented value is missing | Not documented | Both arms, both legs and trunkModel sources |
Fat-free mass is not pure muscle mass. A single result is not a diagnosis. Different devices and similarly named metrics may use definitions that are not interchangeable.